Specifications
|
|
Input
|
|
Input Voltage
|
85-264 VAC (120-370 VDC) derate load from 100% at 90 VAC to 90% at 85 VAC
|
|
Input Frequency
|
47-63 Hz
|
|
Input Current
|
ECE20: 0.3 A rms at 230 VAC ECE40: 0.5 A rms at 230 VAC
|
|
Inrush Current
|
20 A at 115 VAC, 40 A at 230 VAC, cold start at 25 °C
|
|
Power Factor
|
EN61000-3-2 Class A
|
|
Earth Leakage Current
|
Class II construction no earth
|
|
No Load Input Power
|
<0.3 W
|
|
Input Protection
|
ECE20: Internal T1 A/250 VAC fuse ECE40: Internal T2 A/250 VAC fuse
|
|
Output
|
|
Output Voltage
|
See datasheet
|
|
Initial Set Accuracy
|
±1%
|
|
Minimum Load
|
No minimum load required
|
|
Start Up Delay
|
2 s max
|
|
Start Up Rise Time
|
16 ms max
|
|
Hold Up Time
|
8 ms minimum at full load & 115 VAC
|
|
Line Regulation
|
±0.5% max
|
|
Load Regulation
|
±1% max, ±2% max for ECE40US03/05-S
|
|
Transient Response
|
4% max deviation, recovery to within 1% in 500 μs for a 25% load change
|
|
Ripple & Noise
|
3.3-5 V versions: 60 mV pk-pk, 3.3-5 V ‘ECE40-S’ versions: 75 mV pk-pk (see note 5), all other models 1% pk-pk max 20 MHz bandwidth
|
|
Overvoltage Protection
|
115-140% Vnom, auto recovery
|
|
Overload Protection
|
110-180%
|
|
Short Circuit Protection
|
Trip and restart (hiccup mode)
|
|
Temperature Coefficient
|
0.05%/°C
|
|
General
|
|
Efficiency
|
See datasheet
|
|
Isolation
|
3000 VAC Input to Output
|
|
Switching Frequency
|
70 kHz typical
|
|
Power Density
|
ECE20: 9.97 W/In3 ECE40: 7.58 W/In3
|
|
MTBF
|
>450 kHrs to MIL-HDBK-217F at 25 °C, GB
|
|
Environmental
|
|
Operating Temperature
|
-25 °C to +70 °C, derate linearly from 100% at +50 °C to 50% at +70 °C
|
|
Cooling
|
Convection-cooled
|
|
Operating Humidity
|
95% RH, non-condensing
|
|
Storage Temperature
|
-40 °C to +85 °C
|
|
Operating Altitude
|
3000 m
|
|
Vibration
|
2 g, 10 Hz to 500 kHz, 10 mins/cycle, 60 mins each cycle
|
|
EMC and Safety
|
|
Emissions
|
EN55022, level B conducted & radiated
|
|
Harmonic Currents
|
EN61000-3-2, EN61000-3-3
|
|
ESD Immunity
|
EN61000-4-2, level 3 Perf Criteria A
|
|
Radiated Immunity
|
EN61000-4-3, 10 V/m 80% mod Perf Criteria A
|
|
EFT/Burst
|
EN61000-4-4, level 3 Perf Criteria A
|
|
Surge
|
EN61000-4-5, installation Class 3, Perf Criteria A
|
|
Conducted Immunity
|
EN61000-4-6, 10 Vrms Perf Criteria A
|
|
Magnetic Fields
|
EN61000-4-8, 10 A/m Perf Criteria A
|
|
Dips & Interruptions
|
EN61000-4-11, 30% for 10 ms, 60% for 100 ms, 100% for 5000 ms Perf Criteria A, B, B
|
|
Safety Approvals
|
EN60950-1, UL60950-1, CSA22.2 No. 234 per cUL
|